Identifies the displays currently selected for each of the
display attributes: error, input, instruction, output, program,
prompt, scroll, and source.
NOTE
This command is not available in the HP DECwindows Motif for
OpenVMS user interface to the debugger.
Format
SHOW SELECT
1 – Description
The display attributes have the following properties:
o A display that has the error attribute displays debugger
diagnostic messages.
o A display that has the input attribute echoes your debugger
input.
o A display that has the instruction attribute displays the
decoded instruction stream of the routine being debugged.
The display is updated when you enter an EXAMINE/INSTRUCTION
command.
o A display that has the output attribute displays any debugger
output that is not directed to another display.
o A display that has the program attribute displays program
input and output. Currently only the PROMPT display can have
the program attribute.
o A display that has the prompt attribute is where the debugger
prompts for input. Currently, only the PROMPT display can have
the PROMPT attribute.
o A display that has the scroll attribute is the default display
for the SCROLL, MOVE, and EXPAND commands.
o A display that has the source attribute displays the source
code of the module being debugged, if available. The display
is updated when you enter a TYPE or EXAMINE/SOURCE command.
Related commands:
SELECT
SHOW DISPLAY
2 – Example
DBG> SHOW SELECT
display selections:
scroll = SRC
input = none
output = OUT
error = PROMPT
source = SRC
instruction = none
program = PROMPT
prompt = PROMPT
DBG>
The SHOW SELECT command identifies the displays currently
selected for each of the display attributes. These selections